Wireless 4Mbps Point-to-Point Link Data Sheet  
 
 Radio Technology

 Frequency bands 2.4 GHz 2.5 GHz
  5,725 - 5,850 GHz 2.7 - 2.9 GHz
    3.4 - 3.8 GHz

 Duplex Mode TDD for all bands FDD for 3.4 - 3.8 GHz

 Radio Technology FH-CDMA FH-CDMA

 Multiple Access Method PPMA PPMA

 Output Power max. 27 dBm max. 27 dBm
  configurable depending on national regualtions

 Antenna Type PPR internal 15/18 dBi, External SPR internal 15/18 dBi, External

 Sub-Channel Spacing 1 MHz 1 MHz

 Modulation Multilevel (2,4 or 8) CPFSK Multilevel (2,4 or 8) CPFSK

 Receiver Sensitivity
 (BER 1E-6 @ 2/4/8 FSK)
-90/-83/-75 dBm -90/-83/-75 dBm

 Throughput Up to 4Mbps per PPR - SPR link Up to 4Mbps per PPR - SPR link

 Link Range 2.4 GHz: exceeds 30Km 2.5 GHz: exceeds 25Km
 (with internal antennae) 5.8 GHz: exceeds 20Km 2.7 - 2.9 GHz: exceeds 25Km
    3.4 - 3.8 GHz: exceeds 25Km
  Longer ranges can be supported with external antennae

 External Antennae 24dBi at 2.4/2.5/2.7/3.5 GHz, 28dBi at 5.8 GHz

 Radio Standards ETSI EN 300 328-1, ETSI EN 301 253 FCC part 15, RSS139, Telec
 Compliance  

 EMC ETS 300 826, EN 300 385, EN 300 386-2, ETS 300 132-2
  FCC part 15  

 
 Networking

 Protocols IP Routing & PPPoE Bridging, Transparent Bridging, 802.1q/p, DHCP relay

 QoS Based on 802.1p, DiffServe/TOS, IP addresses, protocols or applications

 Security Authentication, Encryption, de-facto VPNs and IP filters based on IP addresses,
  protocols or applications

 Service Classes CIR, MIR

 RFC's 768, 783, 791, 792, 826, 894, 903, 950, 1009, 1027, 1042, 1157, 1213, 1284, 1350, 1878

 
 Management

 Remote Management SNMP, Standard and Private MIB's

 Local Management RS-232 (including PDA) or SNMP

 Software Upgrade Local or remote via TFTP, online

 Management Tools GUI based Element Manager, DataBase (ODBC)


 Mechanical and Electrical Specifications

 PPR Outdoor Unit Indoor Unit

 Interfaces DB15, 10 Base-T DB15, 10 Base-T
  RF: N-Type female (optional) 1xRJ-45 10Base-T or 4xRJ45 10 Base-T

 Power Requirements 30 - 55 VDC, 12 W max. 90 - 264 VAC, 50/60 Hz 50 W max.

 Dimensions H/W/D (mm) 317 x 400 x 65.5 200 x 150 x 40

 Weight 4.7 Kg 0.47 Kg or 0.53 Kg

 
 SPR Outdoor Unit Indoor Unit

 Interfaces DB15, 10 Base-T DB15, 10 Bas3-T
  N type Female (optional) 1 RJ-45 10 Base-T or 4 RJ-45 10 Base-T

 Power Requirements 30 - 55 VDC, 12 W max. 90 - 264 VAC, 50/60 Hz, 50 W max.

 Dimensions H/W/D (mm) 317 x 400 x 65.5 200 x 150 x 40

 Weight 4.7 Kg 0.47 Kg or 0.53 Kg

 
 Environmental

  Outdoor Unit Indoor Unit

 Operating Temperature -30°C to +60°C 0°C to +50°C

 
 Standards Compliance, General

 Safety EN 60950, UL 1950

 Environmental ETS 300 019

2000-2004. All rights reserved World on IP